The Solar Yield calculator is deliberately simple. You should be able to read its method in a few minutes and decide for yourself whether to trust it. This page sets out what it does and what it leaves out. It also shows how it differs from the estimate an installer must give you.
We last reviewed the site against its sources on 10 October 2026.
The generation formula
The calculator estimates yearly generation in one line. Annual generation in kWh equals array kWp times a regional kWh per kWp factor times an orientation factor times a shade factor.
The regional factors are 950 for Southern England, 900 for the Midlands and East and 890 for Wales. Northern England uses 840, Northern Ireland 820 and Scotland 780.
The orientation factors run from 1.00 for south-ish down to 0.65 for mostly north. The shade factors run from 1.00 down to 0.55. The calculator guide lists them all.
The value formula
Value comes in a second step. Self-used kWh equals generation times your self-use share. Exported kWh is generation minus the self-used amount.
Annual value is self-used kWh times your import rate plus exported kWh times your export rate. You type in both rates. The model uses them as given and does not check them against any tariff.
Where the regional factors come from
The factors are editorial round numbers, and we chose them to be cautious. They are not forecasts, and they are not copied from a single source. To test them, we compared them with PVGIS, the European Commission’s solar model.
PVGIS gives 1,019 kWh per kWp for London, 886 for Manchester, 853 for Glasgow and 919 for Belfast. Those runs assume a south-facing roof at a 35 degree tilt and a 14% system loss. The calculator’s matching regional factors of 950, 840, 780 and 820 sit about 5% to 11% lower. Wales is the widest gap, because PVGIS gives 1,042 for Cardiff against the calculator’s 890.
The deliberate gap guards against optimism. However, it also means the calculator can understate output on a good south roof, which is a safer error than overstating it.
What the model leaves out
Several things that matter over a system’s life are outside the model. For example, it treats every year alike.
- Standing charges, which solar does not reduce.
- Tariff changes and the end of the temporary 0% VAT on electricity on 31 March 2027.
- Panel ageing. An NREL review of nearly 2,000 measured rates found a median loss of 0.5% a year.
- Inverter replacement, maintenance and finance costs.
- Battery cost and behaviour.
- Month-by-month and hour-by-hour patterns.
Because of these gaps, the pound figure is an indicative screen. Our guide to interpreting a solar yield result explains how to read it. For the physics behind the factors, see what affects solar yield.
How MCS MIS 3002 differs
Installers certified under MCS must follow the MIS 3002 standard. We read issue 5.0 of MIS 3002. MCS says it issued version 6.0 in March 2026, so ask your installer which issue they use.
Under the standard, the installer multiplies installed kWp by a table value and then by a shade factor. The table value depends on your postcode zone, roof pitch and orientation. The shade factor is a number between 0 and 1, where 1.00 means a clear horizon with no near or far shading.
The differences are plain. MCS uses your real roof, where the calculator uses six regions. MCS uses a surveyed shade factor, where the calculator offers four shade bands.
The MCS estimate must reach you before you sign the contract. It must also warn that performance is impossible to predict with certainty. The figure is guidance for the first year only.
What each method is good for
The calculator is good for learning, since it shows how size, direction and shade interact. It also lets you test tariffs in seconds. The MCS estimate is good for a decision, because it is specific to your site and the installer stands behind it.
Use the calculator before you ask for quotes. Then compare it with the written estimate. However, a large gap is a prompt to ask questions, not proof that either figure is wrong. Our article on kWh per kWp shows how to make that comparison.
Known limits and corrections
The model assumes one typical year. It does not model the slow decline described in solar panel degradation. As a result, year-25 output will be lower than year one.
The calculator runs only in your browser and sends nothing to a server. If you find an error in the method or a source, tell us through the contact page. We will correct it and note the change.
If you plan to buy, see what a proper solar panel installation involves.
Next steps
Use the solar yield calculator to build your own estimate. Then ask for a site-specific written estimate through get quotes. Solar Yield passes enquiries to MCS-certified installers and does not install panels.