The Solar Yield calculator gives you a first estimate of a home solar array’s yearly output and its worth. It is a simple model, so you can follow it line by line. You will find the live tool on the home page.
This guide explains every input, the formula behind it and the places where it stops being reliable.
What the calculator asks for
The tool has seven inputs, and each one changes the answer in a way you can predict.
- Array capacity. A slider from 1 kWp to 12 kWp, set to 4 kWp by default. Many UK homes fit between about 2 kWp and 6 kWp.
- Broad UK region. Six choices, each with a kWh per kWp factor.
- Orientation. Four choices that scale the regional figure.
- Shading. Four choices from little or none to heavy.
- Self-use share. The part of your output you use as it is made, from 10% to 90%, set to 45% by default.
- Import tariff avoided. The price in pence per kWh of the electricity you no longer buy. It starts at 25p.
- Export tariff entered. The price in pence per kWh for what you send to the grid. It starts at 5p.
The tariff boxes hold example values, not live prices. For instance, the Ofgem price cap sets an average unit rate of 26.32p per kWh for October to December 2026. Your own bill and tariff are what count, so overwrite the 25p example.
The regional factors
The calculator uses one kWh per kWp factor for each broad region. Southern England uses 950, Midlands and East 900, Wales 890, Northern England 840, Northern Ireland 820 and Scotland 780.
These are editorial round numbers, not outputs from a weather model. For comparison, the European Commission’s PVGIS tool gives 1,019 kWh per kWp for London and 853 kWh per kWp for Glasgow. Those figures assume a south-facing roof at a 35 degree tilt. The calculator’s factors sit lower because they leave room for everyday losses and cloudier years.
The formula
The calculator multiplies four numbers to get yearly generation. Specifically, annual generation equals array kWp times the regional factor times the orientation factor times the shade factor.
However, orientation and shade also scale the answer. The orientation factors are 1.00 for south-ish, 0.86 for east or west, 0.90 for flat or optimised and 0.65 for mostly north. The shade factors are 1.00 for little or none, 0.90 for light, 0.75 for moderate and 0.55 for heavy.
The value step then splits that generation in two. Self-used kWh equals generation times your self-use share. Exported kWh is the remainder. Annual value is self-used kWh times your import rate, plus exported kWh times your export rate.
A worked example
Take the defaults with a south-ish roof in southern England and no shade. Generation is 4 times 950 times 1.00 times 1.00, which is 3,800 kWh a year.
At a 45% self-use share, you use 1,710 kWh at home and export 2,090 kWh. At 25p and 5p that is about £428 of avoided imports plus about £105 of export income. The calculator shows roughly £532 of modelled annual value.
Now change one thing. If you move the same array to a mostly north roof, generation falls to 2,470 kWh. The value drops with it, so the sliders show quickly which choices matter most. Our guide to what affects solar yield explains why.
What the result does not include
The model leaves out several costs and changes that matter over a system’s life. In particular, it does not include standing charges, VAT changes, tariff rises, panel ageing, inverter replacement or finance costs. Read how to interpret a solar yield result before you use the pound figure for a decision.
The self-use share is the most uncertain input. A home that is empty all day uses a smaller share than one with someone in. Test a low, central and high share rather than trusting one.
How to use it well
Start with your real roof direction and a cautious shade choice. Then replace the example tariffs with those from your latest bill and your supplier’s export rate. After that, compare a pessimistic and an optimistic run, as set out in how to compare solar yield scenarios.
For a sense of real output, see the worked numbers in how much electricity a 4kW solar system generates. Winter matters too, because summer months make up most of the year’s total. Solar panel output in winter shows the monthly pattern.
Where the calculator stops
The calculator cannot see your roof, so it does not know your pitch, your chimney or the tree next door.
A formal estimate under MCS standard MIS 3002 uses your postcode zone, your roof pitch and orientation and a surveyed shade factor. That estimate must reach you before you sign a contract. Our methodology page sets out how the two approaches differ.
If you are still deciding what to buy, our guide to solar panel installation explains what a survey and install involve.
Next steps
Run the numbers on the home page calculator first. When you want site-specific figures, the enquiry form passes your details to MCS-certified installers who can survey your roof. Solar Yield refers enquiries and does not install panels itself.